DRILLBITS
Monthly eNewsletter from the IADC




IADC Lexicon Featured Term for February 2023

The IADC Lexicon is an oil and gas dictionary of upstream-related terms, which, unlike conventional glossaries, are official definitions drawn from legislation, regulation and regulatory guidance, standards (global, national and regional), IADC guidelines, and Well Control Institute. Terms often have multiple definitions from different sources.

This month’s featured term is:

Deadlegs

Components of a piping system that normally have little or no significant flow. Some examples include blanked (blinded) branches, lines with normally closed block valves, lines with one end blanked, pressurized dummy support legs, stagnant control valve bypass piping, spare pump piping, level bridles, pressure relieving device inlet and outlet header piping, pump trim bypass lines, high-point vents, sample points, drains, bleeders, and instrument connections. Deadlegs also include piping that is no longer in use but still connected to the process.

Source: API 570, Piping Inspection Code: In-service Inspection, Rating, Repair, and Alteration of Piping Systems, Fourth Edition, February 2016, with Addendum May 2017. Global Standards